Category:LV switchgear
Company brand:HAOCHENG
Tel:0757-85801981
Address:No. 32, Commercial Plaza, North District, Xingye North Road, Shishan Town, Nanhai District, Foshan City
Intro:GCS series are low voltage switchgear(MCC) suitable in the power generation system and power supply system with three-phase AC 50Hz, rated working voltage of 400V(660V) and rated current of 5000A and below for the collective control and capacitance compensation of power, power distribution and electromotor. It's widely applied in the power station, petroleum, chemical engineering, metallurgy, textile, high-rise buildings as well as the sites which have interface with computer with high automation degrees such as the large-scale power station, etc.
Product description
GCS series are low voltage switchgear(MCC) suitable in the power generation system and power supply system with three-phase AC 50Hz, rated working voltage of 400V(660V) and rated current of 5000A and below for the collective control and capacitance compensation of power, power distribution and electromotor. It's widely applied in the power station, petroleum, chemical engineering, metallurgy, textile, high-rise buildings as well as the sites which have interface with computer with high automation degrees such as the large-scale power station, etc.
Construction features
1. Compact structure, less space installed with more function unit
2. Spare parts are universal, flexible assembly.
3. Adopting standard module design. 5 types of modules for user options.
4. High performance, rated short time withstand current of GCS panel is 80kA, Horizontal busbar arranged with counter flat mode, which can bear peak withstand current 176kA.
5. The partition between function unit / compartment is clear and reliable,there is no affect to adjacent units due to fault of one unit, ensure the fault only happened partially.
Main parameter
Rated voltage of main circuit(V) | AC 380V/400V/660V | |
Rated voltage of secondary circuit(V) | AC 220V/380V(440V), DC 110,220 | |
Rated frequency(Hz) | 50(60) | |
Rated insulation level(V) | 660(1000) | |
Rated current(A) | Horizontal busbar | ≦4000 |
Vertical busbar (MCC) | 1000 | |
Short time withstand current of busbar(KA/1S) | 50,80 | |
Rated peak withstand current of busbar(KA/0.1S) | 105,176 | |
(V/1min) power frequency test voltage | Main circuit | 2500 |
Secondary circuit | 1760 | |
Busbar | 3 phase 4 wire system | A,B,C,PEN |
3 phase 5 wire system | A,B,C,PE,N | |
IP class | IP30,IP40 | |
Outline dimension | Width | 600, 800,1000,1200 |
Depth | 600, 800,1000,1200 | |
Height | 2200 |